Version compatibility catalog
You might encounter the following version compatibility catalog issues. See Component compatibility catalog for the configuration reference.
Startup errors
Platform fails to start after you set a catalog source
The document at TOWER_CATALOG_SOURCE is unreadable or unparseable. Platform validates the catalog document at startup and refuses to boot rather than run without a catalog.
To resolve, confirm the value starts with file: (for example, file:/path/to/state.json), the file is readable by the Platform process, and it is a complete catalog document. A truncated document is not a valid pin.
Platform fails to start with the source set to licman
Platform could not resolve a Seqera License Manager URL.
To resolve, set TOWER_CATALOG_LICMAN_URL, or confirm license.server.url is configured for the deployment.
Launch errors
The deployed ... version could not be determined
Full message:
The deployed <component> version could not be determined. Ask your administrator to check the service's /service-info endpoint and try again
A service carrying catalog compatibility rules has no discoverable version, which means the launch cannot be validated. Platform discovers these versions from each configured service's /service-info endpoint.
To resolve, confirm the service URL is configured and its /service-info endpoint is reachable from Platform, then launch again.